The principle

Principle

Degassing is conducted by feeding a reagent into a degassing tube within a vacuum chamber, controlling the vacuum rate within the vacuum chamber and eliminating the dissolved gas in the reagent by selectively permeating through a face of the degassing tube.


1.DEGASYS DG-1000~5000 Series

DEGASYS DG-1000~5000 Series
  • Dissolved gas flowing in the degassing tube stored in the vacuum chamber is eliminated in-line.
  • Maximum flow rate: 0.5·7·15·50ml, Flow channel of 1~4 ch.
    (1~6 ch. for analytical use) as standard equipment
  • Micro LC, analytical, analytical / semi preparative isolation , and preparative isolation types are available to suit the needs.

Specification

charts
For Micro LC

・Maximum working flow rate may vary on the use and solvent type. The values are for reference only.
・When deionized water of 20~25°c is liquid fed at 0.2ml

For Analytical Use

・Maximum working flow rate may vary on the use and solvent type. The values are for reference only.
・When deionized water of 20~25°c is liquid fed at 1ml

For Aanalytical / Semi Preparative Isolation Use
・Maximum working flow rate may vary on the use and solvent type. The values are for reference only.
・When deionized water of 20~25°c is liquid fed at 5ml
For Preparative Isolation Use

・Maximum working flow rate may vary on the use and solvent type. The values are for reference only.
・When deionized water of 20~25°c is liquid fed at 10ml


2.DEGASYS DG-6000 Series

DEGASYS DG-6000 Series
  • Dissolved gas in the solvent is continuously degassed in-line
  • Small packaging and well balanced to the flow equipment within the system. 24 types available having maximum flow rate of 1·3·10ml, flow channel 1~8ch as standard.
  • Types used for micro HPLC, semi-micro HPLC and HPLC are available.

Specification

charts
For Micro HPLC Use

・Maximum working flow rate may vary on the use and solvent type. The values are for reference only.
・When deionized water of 20~25°c is liquid fed at 0.1ml

For Semi Micro HPLC Use

・Maximum working flow rate may vary on the use and solvent type. The values are for reference only.
・When deionized water of 20~25°c is liquid fed at 0.5ml

For Micro HPLC Use

・Maximum working flow rate may vary on the use and solvent type. The values are for reference only.
・When deionized water of 20~25°c is liquid fed at 1ml


Embedded OEM module type also available for production


For On-Line CatalogueDEGASYS
DG-6000 Catalogue(Japanese)